Basic Info.

Model NO.
RT-VB
Medium Material
Fiberglass
Efficiency
F8,F9,E10,E11,E12,H13,H14
Filtration Grade
HEPA Filter
Type
V Bank Filter
Filter Object
0.5
CMH
2200/4200
Thickness(mm)
292/400/440
Frame
Plastic/Gi/Ai
Initial Resistance
250PA
Header Thickness(mm)
20/25
Transport Package
Carton Box
Specification
customized
Trademark
RT
Origin
China
HS Code
8421999090
Production Capacity
5000pieces/Week

Product Description

Product Description
Clean Room Air Filter V Bank HEPA Filter
Clean Room Air Filter V Bank HEPA FilterClean Room Air Filter V Bank HEPA Filter

Application

It is suitable for the final stage of filtration in various ventilation equipment, dust removal equipment, and air supply systems with
high requirements for cleanliness.

 

Features
Large filtration area and large dust holding capacity
Uniform pleat spacing.
High air flow and low resistance.
Water and moisture resistance.
Resistance to temperature ≤ 50°C.
Humidity resistance (relative humidity) ≤ 100% 
 

Specification

V Bank HEPA Filter - Flange type(GI frame)
Model Size
(mm)
CMH I.N.P
(Pa)
F.N.P
(Pa)
Filter
object
(μm)
EFF.
(%)
Filtration
Class
Filtration
Area
(m2)
Header thickness
(mm)
RT-VB8805FM-5V08 610*610*292-5V 2200/4200 <65/120 <450/600 90≤E<95 0.5 F8 23.82 20/25
RT-VB8805FM-4V08 610*610*292-4V 1800/3600 <65/120 <450/600 90≤E<95 0.5 F8 19.06 20/25
RT-VB8205FM-4V08 610*305*292-4V 1000/2000 <65/120 <450/600 90≤E<95 0.5 F8 9.41 20/25
RT-VB8805FM-5V09 610*610*292-5V 2200/4200 <75/135 <450/600 95≤E 0.5 F9 23.82 20/25
RT-VB8805FM-4V09 610*610*292-4V 1800/3600 <75/135 <450/600 95≤E 0.5 F9 19.06 20/25
RT-VB8205FM-4V09 610*305*292-4V 1000/2000 <75/135 <450/600 95≤E 0.5 F9 9.41 20/25
RT-VB8805FM-5V10 610*610*292-5V 2200/4200 <90/160 <450/600 85≤E<95 0.3 E10 23.82 20/25
RT-VB8805FM-4V10 610*610*292-4V 1800/3600 <90/160 <450/600 85≤E<95 0.3 E10 19.06 20/25
RT-VB8205FM-4V10 610*305*292-4V 1000/2000 <90/160 <450/600 85≤E<95 0.3 E10 9.41 20/25
RT-VB8805FM-5V11 610*610*292-5V 2200/4200 <110/190 <450/600 85≤E<95 0.3 E11 23.82 20/25
RT-VB8805FM-4V11 610*610*292-4V 1800/3600 <110/190 <450/600 85≤E<95 0.3 E11 19.06 20/25
RT-VB8205FM-4V11 610*305*292-4V 1000/2000 <110/190 <450/600 85≤E<95 0.3 E11 9.41 20/25
RT-VB8805FM-5V12 610*610*292-5V 2200/4200 <140/230 <450/600 99.5≤E<99.95 0.3 E12 23.82 20/25
RT-VB8805FM-4V12 610*610*292-4V 1800/3600 <140/230 <450/600 99.5≤E<99.95 0.3 E12 19.06 20/25
RT-VB8205FM-4V12 610*305*292-4V 1000/2000 <140/230 <450/600 99.5≤E<99.95 0.3 E12 9.41 20/25
RT-VB8805FM-5V13 610*610*292-5V 2200/4200 <200/300 <450/600 99.95≤E<99.995 0.3 H13 23.82 20/25
RT-VB8805FM-4V13 610*610*292-4V 1800/3600 <200/300 <450/600 99.95≤E<99.995 0.3 H13 19.06 20/25
RT-VB8205FM-4V13 610*305*292-4V 1000/2000 <200/300 <450/600 99.95≤E<99.995 0.3 H13 9.41 20/25
RT-VB8805FM-5V14 610*610*292-5V 2200/4200 <220/330 <450/600 99.995≤E<99.995 0.3 H14 23.82 20/25
RT-VB8805FM-4V14 610*610*292-4V 1800/3600 <220/330 <450/600 99.995≤E<99.995 0.3 H14 19.06 20/25
RT-VB8205FM-4V14 610*305*292-4V 1000/2000 <220/330 <450/600 99.995≤E<99.995 0.3 H14 9.41 20/25


 

V Bank HEPA Filter- Flange type(Plastic Frame)
Model Size
(mm)
CMH I.N.P
(Pa)
F.N.P
(Pa)
Filter
object
(μm)
EFF.
(%)
Filtration
Class
Filtration
Area
(m2)
Header thickness
(mm)
RT-VB7705FP-4V08 592*592*292-4V 1800/3600 <65/120 <450/600 90≤E<95 0.5 F8 18.81 20/25
RT-VB5105FP-4V08 592*287*292-4V 1000/2000 <65/120 <450/600 90≤E<95 0.5 F8 9.46 20/25
RT-VB7705FPF-4V08 592*592*400-4V 2500/5000 <65/120 <450/600 90≤E<95 0.5 F8 26.20 20
RT-VB5105FPF-4V08 592*287*400-4V 1300/2500 <65/120 <450/600 90≤E<95 0.5 F8 13.18 20
RT-VB7705FPF-4V08 592*592*440-4V 2650/5400 <65/120 <450/600 90≤E<95 0.5 F8 28.93 20
RT-VB5105FPF-4V08 592*287*440-4V 1400/2700 <65/120 <450/600 90≤E<95 0.5 F8 14.55 20
RT-VB7705FP-4V09 592*592*292-4V 1800/3600 <75/135 <450/600 95≤E 0.5 F9 18.81 20/25
RT-VB5105FP-4V09 592*287*292-4V 1000/2000 <75/135 <450/600 95≤E 0.5 F9 9.46 20/25
RT-VB7705FPF-4V09 592*592*400-4V 2500/5000 <75/135 <450/600 95≤E 0.5 F9 26.20 20
RT-VB5105FPF-4V09 592*287*400-4V 1300/2500 <75/135 <450/600 95≤E 0.5 F9 13.18 20
RT-VB7705FPF-4V09 592*592*440-4V 2650/5400 <75/135 <450/600 95≤E 0.5 F9 28.93 20
RT-VB5105FPF-4V09 592*287*440-4V 1400/2700 <75/135 <450/600 95≤E 0.5 F9 14.55 20
RT-VB7705FP-4V10 592*592*292-4V 1800/3600 <90/160 <450/600 85≤E<95 0.3 E10 18.81 20/25
RT-VB5105FP-4V10 592*287*292-4V 1000/2000 <90/160 <450/600 85≤E<95 0.3 E10 9.46 20/25
RT-VB7705FPF-4V10 592*592*400-4V 2500/5000 <90/160 <450/600 85≤E<95 0.3 E10 26.20 20
RT-VB5105FPF-4V10 592*287*400-4V 1300/2500 <90/160 <450/600 85≤E<95 0.3 E10 13.18 20
RT-VB7705FPF-4V10 592*592*440-4V 2650/5400 <90/160 <450/600 85≤E<95 0.3 E10 28.93 20
RT-VB5105FPF-4V10 592*287*440-4V 1400/2700 <90/160 <450/600 85≤E<95 0.3 E10 14.55 20
RT-VB7705FP-4V12 592*592*292-4V 1800/3600 <140/230 <450/600 99.5≤E<99.95 0.3 E12 18.81 20/25
RT-VB5105FP-4V12 592*287*292-4V 1000/2000 <140/230 <450/600 99.5≤E<99.95 0.3 E12 9.46 20/25
RT-VB7705FPF-4V12 592*592*400-4V 2500/5000 <140/230 <450/600 99.5≤E<99.95 0.3 E12 26.20 20
RT-VB5105FPF-4V12 592*287*400-4V 1300/2500 <140/230 <450/600 99.5≤E<99.95 0.3 E12 13.18 20
RT-VB7705FPF-4V12 592*592*440-4V 2650/5400 <140/230 <450/600 99.5≤E<99.95 0.3 E12 28.93 20
RT-VB5105FPF-4V12 592*287*440-4V 1400/2700 <140/230 <450/600 99.5≤E<99.95 0.3 E12 14.55 20
RT-VB7705FP-4V13 592*592*292-4V 1800/3600 <200/300 <450/600 99.95≤E<99.995 0.3 H13 18.81 20/25
RT-VB5105FP-4V13 592*287*292-4V 1000/2000 <200/300 <450/600 99.95≤E<99.995 0.3 H13 9.46 20/25
RT-VB7705FPF-4V13 592*592*400-4V 2500/5000 <200/300 <450/600 99.95≤E<99.995 0.3 H13 26.20 20
RT-VB5105FPF-4V13 592*287*400-4V 1300/2500 <200/300 <450/600 99.95≤E<99.995 0.3 H13 13.18 20
RT-VB7705FPF-4V13 592*592*440-4V 2650/5400 <200/300 <450/600 99.95≤E<99.995 0.3 H13 28.93 20
RT-VB5105FPF-4V13 592*287*440-4V 1400/2700 <200/300 <450/600 99.95≤E<99.995 0.3 H13 14.55 20


 

V Bank HEPA Filter - Box type
Model Size
(mm)
CMH I.N.P
(Pa)
F.N.P
(Pa)
Filter
object
(μm)
EFF.
(%)
Filtration
Class
Filtration
Area
(m2)
RT-VB8805M-5V08 610*610*292-5V 2200/4200 <65/120 <450/600 90≤E<95 0.5 F8 24.40
RT-VB8805M-4V08 610*610*292-4V 1800/3600 <65/120 <450/600 90≤E<95 0.5 F8 19.52
RT-VB8205M-4V08 610*305*292-4V 1000/2000 <65/120 <450/600 90≤E<95 0.5 F8 9.87
RT-VB8805M-5V09 610*610*292-5V 2200/4200 <75/135 <450/600 95≤E 0.5 F9 24.40
RT-VB8805M-4V09 610*610*292-4V 1800/3600 <75/135 <450/600 95≤E 0.5 F9 19.52
RT-VB8205M-4V09 610*305*292-4V 1000/2000 <75/135 <450/600 95≤E 0.5 F9 9.87
RT-VB8805M-5V10 610*610*292-5V 2200/4200 <90/160 <450/600 85≤E<95 0.3 E10 24.40
RT-VB8805M-4V10 610*610*292-4V 1800/3600 <90/160 <450/600 85≤E<95 0.3 E10 19.52
RT-VB8205M-4V10 610*305*292-4V 1000/2000 <90/160 <450/600 85≤E<95 0.3 E10 9.87
RT-VB8805M-5V11 610*610*292-5V 2200/4200 <110/190 <450/600 85≤E<95 0.3 E11 24.40
RT-VB8805M-4V11 610*610*292-4V 1800/3600 <110/190 <450/600 85≤E<95 0.3 E11 19.52
RT-VB8205M-4V11 610*305*292-4V 1000/2000 <110/190 <450/600 85≤E<95 0.3 E11 9.87
RT-VB8805M-5V12 610*610*292-5V 2200/4200 <140/230 <450/600 99.5≤E<99.95 0.3 E12 24.40
RT-VB8805M-4V12 610*610*292-4V 1800/3600 <140/230 <450/600 99.5≤E<99.95 0.3 E12 19.52
RT-VB8205M-4V12 610*305*292-4V 1000/2000 <140/230 <450/600 99.5≤E<99.95 0.3 E12 9.87
RT-VB8805M-5V13 610*610*292-5V 2200/4200 <200/300 <450/600 99.95≤E<99.995 0.3 H13 24.40
RT-VB8805M-4V13 610*610*292-4V 1800/3600 <200/300 <450/600 99.95≤E<99.995 0.3 H13 19.52
RT-VB8205M-4V13 610*305*292-4V 1000/2000 <200/300 <450/600 99.95≤E<99.995 0.3 H13 9.87
RT-VB8805M-5V14 610*610*292-5V 2200/4200 <220/330 <450/600 99.995≤E<99.9995 0.3 H14 24.40
RT-VB8805M-4V14 610*610*292-4V 1800/3600 <220/330 <450/600 99.995≤E<99.9995 0.3 H14 19.52
RT-VB8205M-4V14 610*305*292-4V 1000/2000 <220/330 <450/600 99.995≤E<99.9995 0.3 H14 9.87

Note: Other specifications can be customized according to demand.
 

Clean Room Air Filter V Bank HEPA Filter
Company Profile

RT Air Filtech is a booming air filters manufacturer, certified by ISO 9001:2015 and ISO14001:2015.


RT provided a full range of air filtration solutions for industries, such as electronics factories, semiconductors,
liquid crystal display, bio-pharmaceutical, food, petrochemical industry, clean room, hospital, rail transit, spray
booth, commercial and residential construction. Today, we are privileged to build up strong partnerships with
more than 300 customers from over 98 countries offering excellent air filters so far.

 

RT offers raw material of air filters and its ready filter to customers.

Air Filter raw material: Paint arrestor fiberglass filter, Ceiling filter, Activated carbon filter, Pre-filter, laminated
mesh filter media, pocket filter roll media, HEPA filter paper, all kinds of frames for filter assembly Finished air
filter: Spray booth filters, Pre-filter, Medium pocket filter, Medium separator filter, Medium V-shaped filter,
HEPA separator filter, Compact HEPA filter, HEPA mini pleat, High-temperature HEPA filter, High-efficiency
air supply, FFU, laminar flow hood, etc.

 

Vision: To be a one-stop air filter supplier, build a superior RT brand
Philosophy: Integrity code, quality first, continuous innovation.
Value: Integrity, quality, win-win.
Quality policy: customer-oriented, quality first, energy saving, environmental protection.


Clean Room Air Filter V Bank HEPA Filter

Our Advantages

Clean Room Air Filter V Bank HEPA Filter
Certifications

Clean Room Air Filter V Bank HEPA Filter

Exhibition&Customers

Clean Room Air Filter V Bank HEPA Filter

FAQ

Q1. What is your terms of packing?
A: Generally, we pack our goods in neutral PE bags.

Q2. What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.

Q3. What is your terms of delivery?
A: EXW, FOB, CFR, CIF, DDU.

Q4. How about your delivery time?
A: Generally, it will take 7 to 10 days after receiving your advance payment. The specific delivery time depends
on the items and the quantity of your order.

Q5. Can you produce according to the samples?
A: Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.

Q6. What is your sample policy?
A: We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and
the courier cost.

Q7. Do you test all your goods before delivery?
A: Yes, we have 100% test before delivery

Q8: How do you make our business long-term and good relationship?
A:1. We keep good quality and competitive price to ensure our customers benefit ;
   2. We respect every customer as our friend and we sincerely do business and make friends with them,no matter where they come from.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier